EICR & Landlord Certificates
EICR & LandlordElectrical CertificatesLoughton, Harlow & Epping
A full periodic inspection carried out by a City & Guilds 2391 qualified tester, with a clear written report the same visit and a certificate you can hand straight to your letting agent or mortgage provider.
NICEIC Approved Contractor · 22 years on the tools · free no-obligation site visit
22 yrs
On the tools since 2004
2391
City & Guilds qualified tester
18th Ed.
BS 7671 qualified
£5m
Public liability insurance
Overview
EICR testing and landlord certificates across Essex and East London
An Electrical Installation Condition Report, usually shortened to EICR, is a formal inspection and test of the fixed wiring in a property: the consumer unit, circuits, sockets, switches, lighting and earthing arrangement. It is not a visual once-over. Every circuit is tested with calibrated instruments for insulation resistance, earth fault loop impedance, RCD operation and polarity, and the results are recorded against the requirements of BS 7671, the UK wiring regulations. The report grades any issues found as C1, C2, C3 or FI, so you know exactly what needs attention and what is simply worth monitoring.
For landlords in Loughton, Harlow, Epping and the surrounding towns, an EICR is now a legal requirement under the Electrical Safety Standards in the Private Rented Sector Regulations. It has to be carried out at least every five years, or at the change of tenancy if that comes sooner, and a copy has to go to the tenant and to the local authority if requested. We work directly with landlords, letting agents and property managers, and we can test a single let or a whole portfolio, issuing certificates as each property is completed rather than making you wait for the full batch.
We also carry out EICRs for homeowners selling or remortgaging, for solicitors handling a purchase, and for anyone who simply wants reassurance about a property with older wiring. Every test is carried out by Ben Skingsley, holder of the City & Guilds 2391 inspection and testing qualification, using calibrated test equipment. Findings are explained in plain terms during the visit, not left to a jargon-heavy document you have to decode afterwards.
Private landlords
Meeting the five-yearly legal EICR requirement for rented property in Loughton, Harlow, Epping, Chigwell and nearby areas, with certificates issued promptly for tenancy paperwork.
Letting and managing agents
Portfolio testing with staggered scheduling so certificates arrive property by property, plus straightforward remedial quotes when a report identifies C1 or C2 items.
Homeowners selling or remortgaging
An independent, dated condition report that satisfies solicitors and mortgage lenders and gives buyers confidence in the electrical installation.
Buy-to-let investors
Pre-purchase EICRs on properties you are considering, so unknown rewiring or consumer unit costs are on the table before you exchange, not after.
Leave it, and it gets worse
What happens if an EICR is skipped or left too late
Landlords are legally required to hold a current EICR, and letting without one carries financial and safety consequences that get more expensive the longer they are left. Around 60 words setting the scene before four concrete issues.
Local authority enforcement
Councils can issue improvement notices or financial penalties of up to £30,000 for landlords without a valid EICR when one is required. A letting agent chasing you for a missing certificate at short notice is far more stressful, and often more expensive, than booking the test in good time.
Invalid insurance and voided cover
Landlord insurance policies commonly require compliance with electrical safety regulations. If a fire or fault occurs and there is no current EICR on file, an insurer can refuse or reduce a claim, leaving you to cover repair or liability costs personally.
Tenancy and deposit disputes
Tenants are entitled to see the EICR and can raise it with the council if a landlord fails to provide one. This can complicate deposit disputes, delay tenancy renewals and damage the working relationship with an otherwise good tenant.
Escalating remedial costs
A C2 issue picked up early, such as a worn consumer unit or a circuit without RCD protection, is usually a modest fix. Left for years it can develop into a C1 dangerous condition requiring urgent, more disruptive and more costly work, sometimes during an active tenancy.
Our process
The same five steps on every job
- Step 01
Booking and access arrangements
You tell us the property address, number of circuits or bedrooms, and tenancy status. We agree a visit time directly with you or the tenant, and confirm whether the consumer unit and loft or under-stairs access are reachable.
- Step 02
Visual inspection
We check the consumer unit, visible cabling, accessories, bonding and earthing arrangements for damage, wear, unsafe modifications and non-compliant older installations such as rewireable fuses or lack of RCD protection.
- Step 03
Dead and live testing
Using calibrated instruments we test insulation resistance, earth fault loop impedance, polarity and RCD trip times on every circuit, isolating power briefly where required and restoring it as each test completes.
- Step 04
Grading and report writing
Findings are classified C1 (danger present), C2 (potentially dangerous), C3 (improvement recommended) or FI (further investigation). We talk you through anything found before we leave, so there are no surprises in the paperwork.
- Step 05
Certificate issue and remedial quote
The EICR is issued as a PDF, usually within a day or two for a single property. If C1 or C2 items are found we provide a clear, itemised quote for the remedial work, with no obligation to use us to carry it out.
What you get
Specific outcomes, not promises
Same-visit clarity
You get a verbal summary of any faults before we leave the property, so you are not waiting on a written report to know whether action is needed urgently.
Qualified testing, not a guess
Testing is carried out by a City & Guilds 2391 qualified inspector against BS 7671, using calibrated instruments rather than a visual walk-round.
Reduced long-term risk
Catching a C2 fault at inspection stage, such as a missing RCBO or degraded bonding, prevents it developing into a dangerous C1 condition later.
Straightforward remedial pricing
Any recommended work is quoted in plain figures at the time of inspection, so budgeting for fixes does not involve a second visit or a delay.
One contractor for test and repair
As NICEIC Approved Contractors we can carry out both the EICR and any resulting remedial work, avoiding the back-and-forth of coordinating separate firms.
Portfolio-friendly scheduling
Agents and landlords with several properties get certificates issued as each one is completed, rather than a single bottleneck at the end of a long survey run.
In detail
How EICR testing and grading actually works
An EICR is a technical document, not a checklist tick. Understanding what gets tested, how faults are graded, and how domestic and commercial reports differ helps you interpret the certificate you receive rather than just filing it away.
Test instruments and measurements taken
Every circuit is tested for continuity of protective conductors, insulation resistance between live conductors and earth, polarity, and earth fault loop impedance (Zs) to confirm disconnection times comply with BS 7671. RCDs and RCBOs are tested at rated tripping current and at five times rated current to confirm they operate within the required time limits. Where a consumer unit uses older wire fuses or lacks RCD protection on socket circuits, this is recorded as a departure from current regulations even though it may not always warrant a C1 or C2 code on its own.
Results are compared against the maximum permitted values for the circuit's protective device and cable size, not just against a pass or fail threshold. A ring final circuit reading that suggests a broken ring, for example, will be investigated further with continuity testing at each socket rather than simply noted and left, because an intact ring is fundamental to how that circuit shares load safely.
Grading system: C1, C2, C3 and FI
C1 means danger is present and there is a risk of injury; this requires immediate action and we will explain the risk on site rather than leaving it in a document you read later. C2 means a potentially dangerous condition, such as a missing main bonding conductor or an overloaded circuit, which needs to be addressed but does not require the power to be isolated on the spot. C3 is an improvement recommendation, often relating to older but still broadly safe installations, and FI (further investigation) is used where a fault is suspected but its extent cannot be confirmed without more invasive testing.
An EICR is issued as unsatisfactory if any C1 or C2 items are found, which is the trigger point most landlords and letting agents care about. A satisfactory report with C3 observations only is still valid and compliant, though we will flag sensible improvements worth planning for at the next consumer unit or rewire.
Domestic lets versus commercial and HMO properties
A standard domestic EICR on a two or three-bedroom rental typically covers a single consumer unit and a manageable number of circuits, and can usually be completed in a few hours with the report following shortly after. Houses in multiple occupation and commercial units are more involved: HMOs often have additional fire alarm and emergency lighting interfaces to consider, communal circuits shared between tenancies, and sometimes multiple distribution boards that each need testing and cross-referencing against the building's layout.
Commercial EICRs, which we carry out under RAMS for site safety, also need to account for three-phase supplies, higher demand circuits and equipment that cannot always be powered down during working hours, so testing is often scheduled outside trading hours. Whatever the property type, the underlying test procedures and BS 7671 requirements are the same; what changes is the scale, the access arrangements and how disruption is managed.
Portfolio testing and staggered certificate delivery
For agents and landlords managing several properties in Loughton, Harlow, Epping, Buckhurst Hill and the wider area, we schedule visits in a batch but issue each EICR as soon as that property's testing and report writing is complete, rather than holding everything until the last address is done. This means compliance deadlines on individual tenancies are met even if another property in the batch needs a return visit for access or a further investigation item.
Questions
EICR & Landlord Certificates, your questions answered
Anything not covered here, call 020 4620 2290. Lines are answered 24 hours and site visits run Monday to Friday 7am–6pm and Saturday 8am–5pm.
How much does an EICR cost?
Pricing is quote-led rather than a published figure, based on the number of circuits, property size and access. Our minimum charge is £150 + VAT. We provide a free, no-obligation site visit and small jobs are usually quoted within a day.
How long does an EICR take?
A typical two or three-bedroom rental takes a few hours on site. Larger properties, HMOs or commercial units with multiple distribution boards take longer, and we will give you a realistic estimate when we see the property.
Is an EICR a legal requirement for landlords?
Yes. Under the Electrical Safety Standards in the Private Rented Sector Regulations, landlords in England must have a valid EICR carried out at least every five years, or sooner at change of tenancy, and provide a copy to tenants.
What happens if my EICR comes back unsatisfactory?
We explain any C1 or C2 findings on site and provide a clear, itemised quote for the remedial work. There is no obligation to use us for repairs, though as NICEIC contractors we can usually carry them out promptly.
Do you cover Harlow and Epping as well as Loughton?
Yes, alongside Loughton we regularly work in Harlow, Epping, Chigwell, Buckhurst Hill, Woodford Green, Waltham Abbey, Chingford, Walthamstow, Ilford, Romford and Brentwood.
Can you test a whole portfolio of rental properties?
Yes. We schedule batch visits for agents and landlords and issue each certificate as soon as that property's testing is finished, so individual tenancy compliance deadlines are not held up waiting on the rest of the portfolio.
Is the certificate you issue officially recognised?
Yes. Testing is carried out by a City & Guilds 2391 qualified inspector and we operate as an NICEIC Approved Contractor, so certificates are recognised by councils, letting agents, mortgage lenders and insurers.
Can you carry out an EICR at short notice?
Our phone lines are answered 24 hours even though site visits run within our working hours, Monday to Friday 7am to 6pm and Saturday 8am to 5pm. Call to check the nearest available slot for your postcode.
Related services
Often booked alongside this
Consumer Unit Upgrades
Modern RCBO boards that isolate faults circuit by circuit, replacing ageing fuse boxes with a fully certified installation.
Fault Finding & Diagnostics
Methodical testing to trace tripping circuits and intermittent faults to their source, rather than replacing parts on guesswork.
Commercial Maintenance Contracts
Planned and reactive electrical maintenance for warehouses, schools and offices, with clear reporting and 30-day account terms.
Where we work
EICR & Landlord Certificates across Essex and East London
Working out of Chester Cl in Loughton, the team covers the following towns daily. See the areas we cover or get in touch to check your postcode.
- Loughton
- Harlow
- Epping
- Chigwell
- Buckhurst Hill
- Woodford Green
- Waltham Abbey
- Chingford
- Walthamstow
- Ilford
- Romford
- Brentwood
Next step
Book your EICR with a free site visit
Tell us the property type and circuit count and we will arrange a visit, explain any findings on the day, and quote any remedial work clearly before you commit to anything.
Lines answered 24 hours · Mon–Fri 7am–6pm, Sat 8am–5pm on site